Poor indoor air quality in a commercial building comes from several factors working together. The most important are pollutant sources inside the building, temperature and humidity conditions that let mold and bacteria grow faster, and air handling that doesn’t remove contaminants or brings new ones in. Address only one, and the problem usually comes back. That matters because these buildings are where people spend their lives. According to the EPA, Americans spend about 90 percent of their time indoors, where concentrations of some pollutants are often 2 to 5 times higher than typical outdoor levels. For a facility manager, indoor air is not a comfort issue. It affects attendance, complaints, product quality, inspections, and the reputation of the building. This guide explains where indoor air problems come from, where microbes concentrate, how to tell whether your building has a problem, and how to choose a solution that keeps working after the cleaning crew goes home.  

What causes poor indoor air quality in commercial buildings?

Most indoor air problems start inside the building. The EPA states that indoor pollution sources releasing gases or particles into the air are the primary cause of indoor air quality problems, and that inadequate ventilation and high humidity raise those levels further. The sources fall into three groups:
  • Chemical sources: cleaning products, adhesives, carpet, furniture, copiers, and printers that release volatile organic compounds (VOCs), the gases behind “new building” smells.
  • Outdoor air drawn inside: vehicle exhaust from loading docks and parking areas, and pollutants pulled in through poorly placed air intakes.
  • Biological sources: mold, bacteria, and viruses that grow in damp materials or are carried in by the people using the building.
Temperature and humidity set how fast biological contaminants grow. Mold and bacteria multiply faster in warm, damp conditions, so a building that runs warm and humid gives them an advantage. So does a room that heats up when HVAC is set back overnight and on weekends, or a mechanical space that stays warm year-round. Seasonal swings matter too: humid summers and the moisture that collects when systems switch between heating and cooling both speed up growth. Air exchange affects how long pollutants stay, but outdoor air is not automatically clean air. Depending on the location and the season, it can carry pollen, mold spores, vehicle exhaust, smoke, and humidity into the building. Every building needs outdoor air exchange, and the EPA notes that ASHRAE sets minimums of 15 cubic feet per minute (cfm) of outdoor air per person, and 20 cfm per person in offices. Bringing in more outdoor air, though, does nothing to microbes already growing on surfaces or in duct work, and in some conditions it adds to the contamination load.  

Mold, bacteria, and viruses: the biological side of indoor air

Biological contaminants are the part of indoor air quality that grows. Chemicals stay roughly constant once their source is removed. Mold and bacteria multiply wherever moisture and organic material meet, and viruses arrive with every person who walks through the door. Mold is a fungus that spreads by releasing microscopic spores into the air. Spores are present almost everywhere, so the question is never whether spores exist in a building but whether they have a damp place to grow. The EPA puts it simply: “The key to mold control is moisture control.” Mold exposure can irritate the eyes, skin, nose, throat, and lungs, and can trigger asthma attacks in people who are allergic to it. Bacteria live on surfaces, in water, and in the air. Some form biofilms, thin protective layers that stick to surfaces and resist routine cleaning. In food plants and healthcare settings, bacteria such as Listeria and Staphylococcus are the organisms inspectors and infection preventionists watch most closely. Viruses don’t grow on their own in a building, but they travel on airborne particles and settle on surfaces people touch. Respiratory viruses peak each fall and winter, when buildings are closed up, and the same air is recirculated all day.  

Where do mold and bacteria hide in a commercial building?

Microbial growth concentrates in places that stay damp and rarely get checked. In most facilities, the heaviest growth sits where custodial crews don’t routinely look:
  • Duct work, air handlers, and condensate drain pans, where moisture collects and the airflow spreads spores to every room the system serves
  • Ceiling tiles and wall cavities above or behind past leaks
  • Basements, crawl spaces, mechanical rooms, and storage rooms
  • Restrooms, locker rooms, and kitchens, where humidity spikes several times a day
  • Carpet near entrances, windows, and plumbing
  • Cold storage, coolers, and loading docks, where warm humid air meets cold surfaces and condenses
The pattern is predictable. Wherever water leaks, condenses, or sits for more than a day or two, growth follows. The EPA’s mold guide for schools and commercial buildings recommends drying water-damaged materials within 24 to 48 hours and keeping indoor humidity below 60 percent, ideally 30 to 50 percent.  

How do you know if your building has an air quality problem?

The clearest signs are complaint patterns: occupants report headaches, irritated eyes, coughing, or fatigue that ease after they leave the building, or the same areas keep producing musty odors and stains. The only way to know for certain is to measure. Watch for these warning signs:
  • Musty or stale odors that return after cleaning
  • Visible staining or growth on ceiling tiles, walls, vents, or diffusers
  • Condensation on windows, pipes, or duct work
  • Clusters of complaints from one floor, wing, or room
  • Higher absenteeism during cold months than in comparable buildings
  • Spoilage, contamination findings, or failed swabs in production areas
Measuring air quality is harder than it sounds. There are no federal limits for airborne mold, according to the EPA, so a lab result has to be compared against outdoor air and against clean areas of the same building. Traditional air sampling also takes days, because samples are cultured in a lab before results come back. Real-time monitoring closes that gap. Bio-aerosol monitors count airborne particles and flag biological ones as they occur, so a facility can see when and where counts rise, test whether a fix worked, and keep a record for audits.  

How to improve indoor air quality: source control, building conditions and active treatment

The approach that works has three layers: remove or control the source, manage temperature, humidity, and air exchange, then actively treat the air and surfaces that remain. Each layer covers a gap the others leave. Source control comes first. Fix leaks, dry wet materials quickly, clean drain pans, replace stained ceiling tiles, and choose low-VOC products. The EPA’s sick building fact sheet calls source removal an effective approach whenever the source is known and controllable. Temperature, humidity, and air exchange come next. Keep temperature and humidity steady, including nights and weekends when systems are set back. Confirm that outdoor air dampers work, air handlers meet their design airflow, and filters are changed on schedule. Treat outdoor air as something to manage rather than a cure: filter it, and watch outdoor conditions, because more outdoor air can bring more contaminants in. A higher-efficiency filter, rated MERV 13 or above where the system can handle it, captures more fine particles. Air cleaning reaches what air exchange and filtration alone can’t. ASHRAE’s Standard 241, Control of Infectious Aerosols, approved in June 2023, measures protection as “equivalent clean airflow,” which counts outdoor air, filtration, and air disinfection together. The standard treats air cleaning as a legitimate part of the solution, not an add-on.  

Passive and active air cleaning

Most air cleaning technologies are passive. Filters and in-duct UV lights only treat air that travels through the equipment, so a microbe on a desk, a wall, or a food-contact surface is never reached. Active technologies release a purifying agent into the space itself, so they work on surfaces and in the air of the room, not only inside the unit. That difference matters most where contamination lives on surfaces: kitchens, production rooms, exam rooms, locker rooms, and classrooms.  

Is hydrogen peroxide air purification safe for occupied spaces?

Yes, at the low concentrations used for continuous air purification. Hydrogen peroxide occurs naturally in outdoor air, and the federal workplace exposure limit for it is 1 part per million (ppm) averaged over an eight-hour shift. Systems designed for occupied rooms operate far below that limit and break down into water and oxygen. The confusion comes from liquid hydrogen peroxide and fogging. Household peroxide is a liquid solution, and hydrogen peroxide fogging systems flood a sealed room with a high concentration that requires everyone to leave. Continuous systems work differently: they produce a trace amount of hydrogen peroxide gas from the moisture already in the air, so people can keep working while the room is treated. Both OSHA’s permissible exposure limit and NIOSH’s recommended exposure limit for hydrogen peroxide are 1 ppm as an eight-hour time-weighted average. EMT systems produce about 0.03 ppm, roughly one-thirtieth of that limit.  

The EMT 4-Step Solution: from first reading to ongoing protection

Facilities that keep air quality under control treat it as a process, not a one-time cleanup. EMT’s 4-Step Solution runs from the first measurement to long-term protection, and it covers the entire building rather than only the room where a problem was found.
  1. Quantify and identify. Measure the whole building before anything is disturbed. Inspect for leaks, condensation, odors, and hidden growth, and take airborne microbial readings in every room, not just the problem area. Those readings become the baseline used to prove results later.
  2. Decontaminate. Physically remove any mold growth and fix the moisture source first. On mold jobs, that work follows the IICRC S520 remediation standard. Then treat the entire structure, so spores from other parts of the building can’t drift back into the cleaned area, and measure again to confirm the microbial load dropped.
  3. Actively prevent. Install permanent units that keep treating the air and surfaces 24/7, with the right type, number, and placement for each space. Keep temperature steady, hold humidity in the 30 to 50 percent range, and fix leaks quickly.
  4. Monitor and maintain. Take readings after installation and on an ongoing schedule, inspect and service the equipment, and act quickly if readings or conditions change. Keep the results for inspectors, auditors, and tenants.
This process doesn’t replace your cleaning program or professional remediation. Physical removal always comes first. EMT’s role is to treat the whole building around that work and keep protecting it after the crew leaves.  

Where EMT fits in a commercial indoor air quality program

Extreme Microbial Technologies makes Energized Hydrogen Peroxide® air and surface purification systems for schools, food processors, healthcare facilities, hotels, restaurants, and commercial buildings. The technology is active and always on: it produces a trace, safe level of hydrogen peroxide from the moisture already in the air, which travels through the space to reach microbes in the air and on surfaces. It uses no harsh chemicals, leaves no residue, and doesn’t release byproducts into the environment, breaking down into water and oxygen. The product line scales to the building:
  • MAK-Inline installs in existing HVAC duct work to treat a whole building.
  • MAK-9 Wall Unit and MAK-14 treat individual rooms, from classrooms and offices to kitchens and guest rooms, and MAK-414 treats large spaces.
  • MAK-TWIN covers larger industrial and production spaces.
  • X-MAK Super Scrubber handles odor events and heavy contamination.
  • BAMS (Bio-Aerosol Monitoring System) measures airborne microbial levels in real time, so results can be verified after installation.
In company-reported lab testing in real-world rooms up to 1,100 cubic feet, EMT technology reduced viruses, bacteria, and mold by up to 99.9%, including Listeria and Staphylococcus (MRSA) by 99.99%. Testing in actual rooms rather than small lab chambers gives facility managers a more realistic picture of how a system performs once it is installed. EMT supports each installation with real-time monitoring, regular inspections, and cell replacement every 24 months.  

FAQ’s

How often should a commercial building test its indoor air quality?

Test at least once a year to establish a baseline, then again after any water leak, renovation, or cluster of occupant complaints. Facilities with continuous monitoring can track levels every day and act as soon as counts rise.

Can a HEPA filter remove mold from a building?

A HEPA filter captures mold spores in the air that passes through it, which lowers airborne counts. It doesn’t reach mold growing on walls, ceiling tiles, or inside duct work, so the moisture source still has to be fixed and the growth removed.

What humidity level prevents mold indoors?

The EPA recommends keeping indoor relative humidity below 60 percent, and ideally between 30 and 50 percent. Water-damaged materials should be dried within 24 to 48 hours.

Does air purification replace regular cleaning and disinfection?

No. Continuous air and surface purification is an added layer that keeps working between scheduled cleanings, and in places crews can’t reach. Your existing cleaning and sanitation procedures should stay in place.

Start with a clear picture of your air

The most useful first step for any facility is a baseline: know what is in your air and where it comes from before choosing equipment. For more information call (844) 885-0088 or visit www.extrememicrobial.com 

Subscribe for Email Updates

* indicates required

References

ASHRAE. (2023, June 24). ASHRAE approves groundbreaking standard to reduce the risk of disease transmission in indoor spaces [Press release]. https://www.ashrae.org/about/news/2023/ashrae-approves-groundbreaking-standard-to-reduce-the-risk-of-disease-transmission-in-indoor-spaces National Institute for Occupational Safety and Health. (n.d.). Hydrogen peroxide. In NIOSH pocket guide to chemical hazards. Centers for Disease Control and Prevention. Retrieved October 28, 2026, from https://cdc.gov/niosh/npg/npgd0335.html U.S. Environmental Protection Agency. (1991). Indoor air facts no. 4 (revised): Sick building syndrome. https://www.epa.gov/sites/default/files/2014-08/documents/sick_building_factsheet.pdf U.S. Environmental Protection Agency. (2008). Mold remediation in schools and commercial buildings (EPA 402-K-01-001). https://www.epa.gov/sites/default/files/2014-08/documents/moldremediation.pdf U.S. Environmental Protection Agency. (2026a, February 18). A brief guide to mold, moisture and your home. https://www.epa.gov/mold/brief-guide-mold-moisture-and-your-home U.S. Environmental Protection Agency. (2026b, May 27). Indoor air quality. In Report on the environment. https://www.epa.gov/report-environment/indoor-air-quality U.S. Environmental Protection Agency. (2026c, March 19). Introduction to indoor air quality. https://www.epa.gov/indoor-air-quality-iaq/introduction-indoor-air-quality