Sick building syndrome describes a situation where occupants have headaches, eye, nose or throat irritation, fatigue or trouble concentrating that are linked to time spent in a building, with no specific illness or cause identified. The clearest sign is that symptoms ease soon after people leave the building.
For property managers and building owners, sick building syndrome is more than a health complaint. It shows up as service tickets, sick days, unhappy tenants and lease renewals that don’t happen. The good news is that its usual causes are well understood and most are fixable.
This guide explains how to recognize sick building syndrome, what causes it, how it differs from building-related illness, and the steps that bring an office building back under control.
What is sick building syndrome?
The EPA uses the term sick building syndrome for situations in which building occupants experience acute health and comfort effects that appear to be linked to time spent in a building, but no specific illness or cause can be identified. Complaints may come from one room, one floor or the entire building. According to the EPA’s sick building syndrome fact sheet indicators are:- Occupants report symptoms of acute discomfort, such as headache, eye, nose or throat irritation, dry cough, dry or itchy skin, dizziness, nausea, difficulty concentrating, fatigue and sensitivity to odors.
- The cause of the symptoms is not known.
- Most people report relief soon after leaving the building.
How is sick building syndrome different from building-related illness?
Building-related illness is the term used when symptoms of a diagnosable illness are identified and can be attributed directly to airborne building contaminants. Sick building syndrome has no identifiable cause, while building-related illness does, and people with building-related illness may need longer to recover after leaving the building. The distinction matters for how you respond. A suspected building-related illness, such as a respiratory infection traced to contaminated water in a cooling system, calls for an immediate professional investigation and medical follow-up. Sick building syndrome calls for a systematic look at pollutant sources, temperature, moisture and air handling.What causes sick building syndrome?
The EPA identifies four main causes: inadequate ventilation, chemical contaminants from indoor sources, chemical contaminants from outdoor sources, and biological contaminants. In most buildings, more than one is at work at the same time. The list is a general framework, and it leaves out a factor that matters a great deal for mold and bacteria: temperature. Warm, humid conditions speed up microbial growth, so temperature belongs in any investigation.Inadequate ventilation
The EPA calls inadequate ventilation an important factor in sick building syndrome. After the 1973 oil embargo, energy-saving standards cut outdoor air to 5 cubic feet per minute (cfm) per occupant. ASHRAE later restored a minimum of 15 cfm per person, and 20 cfm per person in office spaces. Many buildings still underperform because of stuck dampers, poor air distribution or occupancy that grew after the system was designed. Outdoor air exchange is necessary, but outdoor air is not automatically clean. Depending on the location and season, it can carry pollen, mold spores, vehicle exhaust and humidity into the building. More outdoor air dilutes some indoor pollutants, but it does nothing to microbes already growing on surfaces or in ductwork, and in some conditions it makes the problem worse.Indoor chemical sources
The EPA notes that most indoor air pollution comes from sources inside the building. Adhesives, carpeting, upholstery, manufactured wood products, copiers, pesticides and cleaning agents release volatile organic compounds (VOCs). New furniture and renovations bring a spike in these emissions.Outdoor chemical sources
Outdoor air entering the building can carry pollution of its own. Vehicle exhaust from nearby roads, loading docks and parking garages, and exhaust from the building’s own vents, can be drawn back in through poorly placed air intakes, windows and other openings.Biological contaminants
Bacteria, molds, pollen and viruses are biological contaminants. The EPA notes they can breed in stagnant water that collects in ducts, humidifiers and drain pans, or where water has damaged ceiling tiles, carpet or insulation. Mold and bacteria in the air handling system are especially disruptive because the system distributes them to every space it serves.Signs your office building has an air quality problem
The pattern is predictable. Complaints cluster in time and place, and the building gives physical clues before anyone files a ticket. Look for:- Repeat complaints of headaches, stuffiness or fatigue from the same floor or suite
- Symptoms that improve on weekends and return during the work week
- Stale or stuffy air in meeting rooms by mid-afternoon
- Musty odors near restrooms, kitchens, mechanical rooms or exterior walls
- Water-stained ceiling tiles, condensation on windows or ductwork, or visible growth on diffusers
- Higher absenteeism during winter, when buildings are sealed and air is recirculated
- Problems that started after a renovation, a tenant fit-out or a change to HVAC settings
Does indoor air quality affect productivity and sick days?
Yes. Controlled studies show measurable effects on both thinking and attendance. In a Harvard study of office workers, cognitive scores were 61% higher in low-VOC conditions and 101% higher in low-VOC conditions with increased ventilation, compared with a conventional office environment. That study, by Allen and colleagues in Environmental Health Perspectives, placed 24 participants in a controlled office setting for six full work days, with participants blinded to which conditions they were working in. The largest gains came in decision-making areas such as strategy and information use. Attendance follows the same direction. A summary from Lawrence Berkeley National Laboratory reports that in one office study by Milton and colleagues, a 35% decrease in short-term absence was associated with doubling the ventilation rate from 25 to 50 cfm per person. For an employer, staff costs dwarf energy costs, so even small gains in attendance and focus outweigh the cost of better air. Those studies measured specific buildings in specific conditions, though. More outdoor air helps only when that air is clean and its humidity is controlled, which is why air treatment and monitoring matter as much as airflow.How to fix sick building syndrome in an office building
The EPA’s recommended fixes come down to removing or modifying pollutant sources, increasing ventilation and air distribution, cleaning the air, and communicating with occupants. Treat the ventilation advice with care: more outdoor air only helps when that air is clean, so temperature, humidity and active treatment matter just as much. A structured investigation finds which steps your building needs.- Listen and log. Record every complaint by date, location and symptom. Patterns point to the source faster than any instrument.
- Check the HVAC system. Confirm outdoor air dampers open, measure airflow against design, replace filters and inspect coils, drain pans and humidifiers for standing water and growth.
- Find and remove sources. Relocate copiers to ventilated rooms, schedule painting and carpet work for unoccupied hours, choose low-VOC materials and fix leaks quickly.
- Control moisture and temperature. Keep temperature steady, keep relative humidity below 60 percent and dry water-damaged materials within 24 to 48 hours, as the EPA’s mold guidance recommends.
- Clean the air continuously. Higher-efficiency filtration and air purification reduce what ventilation alone can’t remove, especially biological contaminants.
- Measure and report back. Test before and after changes, and share the results with tenants and staff. The EPA lists education and communication as key parts of any indoor air quality program.
Indoor air quality as a tenant amenity
Tenants increasingly ask about air quality during leasing, and many are measuring it themselves. A building that can show its air quality data, its maintenance records and its air treatment program has an advantage in renewals and new leases. Healthy air has moved from a maintenance line item to part of the building’s value.Seasonal risks property managers often miss
Office air quality follows the calendar. Each seasonal change brings its own risk, and most complaint spikes line up with one of them. Heating and cooling changeover. When a system switches modes after months of inactivity, whatever grew in idle coils, drain pans and ductwork moves into occupied space. Inspecting and cleaning those components before the switch prevents the first-week wave of musty-smell tickets. Winter. Outdoor air dampers are often turned down to save heating costs, and the same air recirculates through the building all day. That is also when respiratory viruses peak. Confirming that outdoor air rates still meet design during cold months is one of the simplest fixes available. Humid summers. Cooling systems that are oversized or short-cycle cool the air without removing enough moisture. Humidity climbs above 60 percent, and mold starts in carpet, ceiling tiles and wall cavities. After a vacancy. Suites that sit empty for months are often left with HVAC set back or off. Before a new tenant moves in, check humidity, flush the space with filtered outdoor air when outdoor conditions are good and inspect for hidden water damage. After a renovation. New carpet, paint, furniture and adhesives release a spike of VOCs. Schedule work for unoccupied hours, run filtered ventilation at higher rates for several weeks after when outdoor air is clean, and let materials air out before tenants return.How to communicate with tenants and staff
How you respond to complaints shapes how occupants feel about the building as much as the fix itself. Acknowledge every complaint quickly, explain what you are checking and share what you found. When people see that complaints lead to action and data, they report problems earlier, which makes them cheaper to fix. A short quarterly air quality update to tenants turns maintenance work into a visible amenity.Where EMT fits in office indoor air quality
Extreme Microbial Technologies makes Energized Hydrogen Peroxide® air and surface purification systems for offices, commercial property, schools, healthcare facilities and food processors. The technology is active and always on: units produce a trace, safe level of hydrogen peroxide from the natural moisture in the air, which moves through occupied spaces to reach mold, bacteria and viruses in the air and on surfaces. Treatment continues during work hours, nights and weekends, uses no harsh chemicals, leaves no residue and doesn’t release byproducts into the environment. For office buildings, two products cover most needs:- MAK-Inline installs in existing HVAC ductwork to treat every space the system serves, which suits multi-tenant and whole-building programs.
- MAK-414 treats large rooms and open areas where a whole-building install isn’t practical.
Frequently asked questions
Can sick building syndrome be diagnosed by a doctor?
No single medical test identifies sick building syndrome, because by definition no specific illness or cause can be found. Doctors may rule out other conditions, while the building itself is investigated through complaint patterns and air quality testing.Is a carbon dioxide reading enough to check office air quality?
Carbon dioxide is a useful indicator of whether a space gets enough outdoor air for its occupancy. It doesn’t measure mold, bacteria, VOCs or particles, so a full assessment combines CO2 readings with other measurements.Who is responsible for fixing sick building syndrome in a leased building?
Responsibility depends on the lease, but the base building HVAC system is usually the owner’s or property manager’s responsibility, while tenant fit-outs and in-suite equipment may fall to the tenant. Clear communication between both sides speeds up the investigation.How long does it take to fix sick building syndrome?
Simple fixes, such as opening dampers, replacing filters or relocating a copier, can bring relief within days. Problems tied to moisture damage or mold in the HVAC system take longer because the source has to be removed and the system cleaned.Make the building part of the solution
Start with the complaint log and the air handlers. Together they usually reveal where the problem lives. To talk with EMT about your building, call (844) 885-0088 or visit www.extrememicrobial.comReferences
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016). Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: A controlled exposure study of green and conventional office environments. Environmental Health Perspectives, 124(6), 805–812. https://doi.org/10.1289/ehp.1510037 Lawrence Berkeley National Laboratory. (n.d.). Ventilation rates and absences in offices and schools. Indoor Air Quality Scientific Findings Resource Bank. https://iaqscience.lbl.gov/node/34 Milton, D. K., Glencross, P. M., & Walters, M. D. (2000). Risk of sick leave associated with outdoor air supply rate, humidification, and occupant complaints. Indoor Air, 10(4), 212–221. https://doi.org/10.1034/j.1600-0668.2000.010004212.x U.S. Environmental Protection Agency. (1991). Sick building syndrome (Indoor Air Facts No. 4, rev.). https://www.epa.gov/sites/default/files/2014-08/documents/sick_building_factsheet.pdf U.S. Environmental Protection Agency. (2026, February 18). A brief guide to mold, moisture and your home. https://www.epa.gov/mold/brief-guide-mold-moisture-and-your-home Views: 7